SKC HSE Air Sampling guide for Captan (ISO)

Chemical Hazard

Captan (ISO)

CAS. No.

133-06-2

Sampling Methodology

MDHS 94/2


Sampling Parameters

Agency Standards (ppm)

Volume

Rate

Time

TWA 5 mg/m3

960 L

2000 ml/min

15 min

C/STEL 15 mg/m3

30 L

2000 ml/min

15 min

Analytical Method

GC-MS


SKC Sampling Equipment

IOM Particulate Sampler:225-70A 

Filter:225-58F 

Sorbent Tube:226-35-01 